Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 12(11)2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34832729

RESUMO

A critical role of the peripheral axons of nociceptors of the dorsal root ganglion (DRG) is the conduction of all-or-nothing action potentials from peripheral nerve endings to the central nervous system for the perception of noxious stimuli. Plasticity along multiple sites along the pain axis has now been widely implicated in the maladaptive changes that occur in pathological pain states such as neuropathic and inflammatory pain. Notably, increasing evidence suggests that nociceptive axons actively participate through the local expression of ion channels, receptors, and signal transduction molecules through axonal mRNA translation machinery that is independent of the soma component. In this report, we explore the sensitization of sensory neurons through the treatment of compartmentalized axon-like structures spanning microchannels that have been treated with the cytokine IL-6 and, subsequently, capsaicin. These data demonstrate the utility of isolating DRG axon-like structures using microfluidic systems, laying the groundwork for constructing the complex in vitro models of cellular networks that are involved in pain signaling for targeted pharmacological and genetic perturbations.

2.
Acta Biomater ; 101: 565-574, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31678740

RESUMO

We have characterized the in vitro and in vivo extracellular neural recording and stimulation properties of ruthenium oxide (RuOx) based microelectrodes. Cytotoxicity and functional neurotoxicity assays were carried out to confirm the in vitro biocompatibility of RuOx. Material extract assays, in accordance to ISO protocol "10993-5: Biological evaluation of medical devices", revealed no significant effect on neuronal cell viability or the functional activity of cortical networks. In vitro microelectrode arrays (MEAs), with indium tin oxide (ITO) sites modified with sputtered iridium oxide (IrOx) and RuOx in a single array, were developed for a direct comparison of electrochemical and recording performance of RuOx to ITO and IrOx deposited microelectrode sites. The impedance of the RuOx-coated electrodes measured by electrochemical impedance spectroscopy was notably lower than that of ITO electrodes, resulting in robust extracellular recordings from cortical networks in vitro. We found comparable signal-to-noise ratios (SNRs) for RuOx and IrOx, both significantly higher than the SNR for ITO. RuOx-based MEAs were also fabricated and implanted in the rat motor cortex to demonstrate manufacturability of the RuOx processing and acute recording capabilities in vivo. We observed single-unit extracellular action potentials with a SNR >22, representing a first step for neurophysiological recordings in vivo with RuOx based microelectrodes. STATEMENT OF SIGNIFICANCE: A critical challenge in neural interface technology is the development of microelectrodes that have recording and electrical stimulation capabilities suitable for bidirectional communication between the external electronic device and the nervous system. The present study explores the feasibility and functional capabilities of ruthenium oxide microelectrodes as a neural interface. Significant improvement in electrochemical properties and neuronal recordings are reported when compared to commercially available indium tin oxide and was similar to that of iridium oxide electrodes. The data demonstrate the potential for future development of chronic neural interfaces using ruthenium oxide based microelectrodes for recording and stimulation.


Assuntos
Encéfalo/fisiologia , Óxidos/farmacologia , Rutênio/farmacologia , Animais , Células Cultivadas , Córtex Cerebral/embriologia , Estimulação Elétrica , Técnicas Eletroquímicas , Embrião de Mamíferos/citologia , Feminino , Camundongos Endogâmicos ICR , Microeletrodos , Neurônios/efeitos dos fármacos , Neurotoxinas/toxicidade , Ratos Long-Evans
3.
Nanotechnology ; 30(23): 235501, 2019 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-30776783

RESUMO

An ideal microelectrode array (MEA) design should include materials and structures which exhibit biocompatibility, low electrode polarization, low impedance/noise, and structural durability. Here, the fabrication of MEAs with indium tin oxide (ITO) electrodes deposited with self-similar gold nanostructures (GNS) is described. We show that fern leaf fractal-like GNS deposited on ITO electrodes are conducive for neural cell attachment and viability while reducing the interfacial impedance more than two orders of magnitude at low frequencies (100-1000 Hz) versus bare ITO. GNS MEAs, with low interfacial impedance, allowed the detection of extracellular action potentials with excellent signal-to-noise ratios (SNR, 20.26 ± 2.14). Additionally, the modified electrodes demonstrated electrochemical and mechanical stability over 29 d in vitro.

4.
ACS Omega ; 4(27): 22332-22344, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31909316

RESUMO

New ether-substituted poly(1,4-phenylene vinylene) (PPV) derivatives were synthesized via Horner-Emmons coupling. The structures of the monomers and the resultant oligomers were confirmed by 1H and 13C NMR spectroscopies. The molecular weights of the oligomers were characterized by gel permeation chromatography, giving the number-average and weight-average molecular weights and the corresponding polydispersity indices. Measurements of UV-vis absorption and fluorescence were used to characterize the optical properties of the oligomers. Estimation of the highest occupied molecular orbital and lowest unoccupied molecular orbital energy levels and other electrochemical characteristics of the oligomers were investigated by cyclic voltammetry. Dialkyl and dialkoxy PPV oligomers were also prepared and characterized following the same instrumental methods used for the ether-substituted oligomers, providing a known reference system to judge the performance of the new conjugated oligomers. Devices were fabricated to analyze the electroluminescent characteristics of the oligomers in organic light-emitting diodes.

5.
Biomed Microdevices ; 20(2): 48, 2018 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-29909439

RESUMO

Substrate-integrated microelectrode arrays (MEAs) are non-invasive platforms for recording supra-threshold signals, i.e. action potentials or spikes, from a variety of cultured electrically active cells, and are useful for pharmacological and toxicological studies. However, the MEA substrate, which is often fabricated using semiconductor processing technology, presents some challenges to the user. Specifically, the electrode encapsulation, which may consist of a variety of inorganic and organic materials, requires a specific substrate preparation protocol to optimize cell adhesion to the surface. Often, these protocols differ from and are more complex than traditional protocols for in vitro cell culture in polystyrene petri dishes. Here, we describe the fabrication of an MEA with indium tin oxide microelectrodes and a patterned polystyrene electrode encapsulation. We demonstrate the electrochemical stability of the electrodes and encapsulation, and show viable cell culture and in vitro recordings.


Assuntos
Eletrofisiologia/instrumentação , Microeletrodos , Neurônios/citologia , Poliestirenos , Animais , Feminino , Camundongos , Gravidez , Propriedades de Superfície
6.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(3 Pt 1): 031915, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21517533

RESUMO

We use a lattice Boltzmann based Brownian dynamics simulation to investigate the dependence of DNA thermophoresis on its interaction with dissolved salts. We find the thermal diffusion coefficient D{T} depends on the molecule size, in contrast with previous simulations without electrostatics. The measured S{T} also depends on the Debye length. This suggests thermophoresis of DNA is influenced by the electrostatic interactions between the polymer beads and the salt ions. However, when electrostatic forces are weak, DNA thermophoresis is not found, suggesting that other repulsive forces such as the excluded volume force prevent thermal migration.


Assuntos
Biofísica/métodos , DNA/química , Sais/química , Cátions , Coloides/química , Simulação por Computador , Difusão , Íons , Modelos Químicos , Modelos Estatísticos , Conformação de Ácido Nucleico , Tamanho da Partícula , Polímeros/química , Eletricidade Estática , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...